DAYTON 2ZWN9 Pump Centrifugal 1/3 Hp 1 Ph 115/230v

Item: AC4HLZ
Model: 2ZWN9
Check Availability
In Stock.

Get it by Monday, Feb 9

£9.99 flat shipping is applicable on orders with an aggregate weight less than 10kg. Orders exceeding 10kg will be charged default shipping rates

We deliver to your doorstep under DAP terms. Customs clearance is for your account

$575.45
10% off
$517.91 /unit (ex. VAT)
Add To Cart
Request Quote

Unlock 30-day payment terms

Business customers can apply for Net 30
No fees, No interest, Fast approval.

Payment

Delivery

Specifications

Item Centrifugal Pump
Amps 7.5/3.8A
Bearing Type Ball
Best Efficiency Flow 30 GPM
Best Efficiency Flow Range @ Head 25 to 37 GPM @ 30 to 25 ft.
Best Efficiency Flow Rate @ Head 30 GPM @ 26 ft.
Best Efficiency Head 26 ft.
Compatible Discharge Pipe Size 3/4"
Compatible Intake Pipe Size 1"
Connection Type NPT
Discharge Type NPT
Drain Plug Side And Bottom
Duty Continuous
Duty Cycle Continuous
Flow Rate @ 1 Ft Of Head (maximum) Not Applicable
Flow Rate @ 10 Ft Of Head (maximum) 41 GPM
Flow Rate @ 100 Ft Of Head (maximum) Not Applicable
Flow Rate @ 120 Ft Of Head (maximum) Not Applicable
Flow Rate @ 140 Ft Of Head (maximum) Not Applicable
Flow Rate @ 15 Ft Of Head (maximum) 37 GPM
Flow Rate @ 160 Ft Of Head (maximum) Not Applicable
Flow Rate @ 180 Ft Of Head (maximum) Not Applicable
Flow Rate @ 20 Ft Of Head (maximum) 34 GPM
Flow Rate @ 200 Ft Of Head (maximum) Not Applicable
Flow Rate @ 220 Ft Of Head (maximum) Not Applicable
Flow Rate @ 240 Ft Of Head (maximum) Not Applicable
Flow Rate @ 260 Ft Of Head (maximum) Not Applicable
Flow Rate @ 280 Ft Of Head (maximum) Not Applicable
Flow Rate @ 30 Ft Of Head (maximum) 25 GPM
Flow Rate @ 300 Ft Of Head (maximum) Not Applicable
Flow Rate @ 5 Ft Of Head (maximum) Not Applicable
Flow Rate @ 50 Ft Of Head (maximum) Not Applicable
Flow Rate @ 60 Ft Of Head (maximum) Not Applicable
Flow Rate @ 70 Ft Of Head (maximum) Not Applicable
Flow Rate @ 80 Ft Of Head (maximum) Not Applicable
Flow Rate @ 90 Ft Of Head (maximum) Not Applicable
For Use With Potable Systems No
Frame 56J
Frequency 60 Hz
Housing Material Cast Iron
Hp 1/3 hp
Hp - Pumps 1/3 hp
Impeller Material Cast Iron
Impeller Type Semi Open
Includes Manual
Inlet Pressure 200 psi
Length 13"
Max. Case Pressure 200 psi
Max. Feet Of Head 40 ft.
Max. Flow Rate 41 GPM
Max. Flow Rate @ 10 Ft. 41 GPM
Max. Flow Rate @ 140 Ft. 37 GPM
Max. Flow Rate @ 15 Ft. 37 GPM
Max. Flow Rate @ 20 Ft. 34 GPM
Max. Flow Rate @ 25 Ft. 29 GPM
Max. Flow Rate @ 30 Ft. 25 GPM
Max. Flow Rate @ 40 Ft. 10 GPM
Max. Flow Rate @ Head 41 GPM @ 10 ft.
Max. Head 44 ft.
Max. Liquid Temp. 200°F
Max. Operating Pressure 18.2 psi
Max. Solid Dia. 1/3"
Max. Specific Gravity 1
Maximum Flow Rate @ 140 Feet Of Head 37 GPM
Maximum Flow Rate @ 40 Feet Of Head 0 GPM
Min. Flow Rate @ Head 10 GPM @ 40 ft.
Motor Enclosure - Pumps Open Dripproof
Motor Enclosure Design Open Dripproof
Motor Frame Designation 56J
Motor Type Capacitor Start
Overall Height 5 1/2"
Overall Length 13"
Overall Width 5 4/5"
Phase 1
Port Rotation Four Position
Pump Housing Material Cast Iron
Rpm 3450 RPM
Rpm (maximum) 3450 RPM
Screw Finish Zinc Plated
Screw Material Steel
Seal Application Long Life When Not Run Dry Or Pumping Abrasives
Seal Material Buna N, Carbon, Ceramic, Stainless Steel
Seal Type Mechanical
Service Factor 1.75
Shaft Material Stainless Steel
Shaft Size 5/8"
Shut Off Pressure 19 psi
Shut Off Pressure (maximum) 19 psi
Solid Diameter (maximum) 9/25"
Specific Gravity 1
Specific Gravity (maximum) 1
Type Centrifugal
Voltage 115/230V AC
Volute Material Cast Iron
Wetted Material Buna N, Carbon, Cast Iron, Ceramic, Stainless Steel
Wetted Materials Buna N, Carbon, Cast Iron, Ceramic, Stainless Steel
Width 5 7/8"
Standards CULUS LISTED

Product Details

Dayton 2ZWN9 centrifugal pump is ideal for dispensing fluid at high pressure and speed. It is used in water supply and distribution, wastewater treatment, irrigation, HVAC systems, chemical processing, oil refining and power generation tasks.

Shipping Information

Height (cm) 13.97
Length (cm) 33.02
Width (cm) 14.73
HS Code 8413702005
Country Of Origin IN
Weight (kg) 14.913

Working Mechanism

  • Ensure that the pump and suction lines are filled with the fluid to be pumped to create a prime, ensuring efficient operation.
  • Switch on the motor that drives the pump, initiating the pumping process.
  • As the motor rotates, it drives the pump impeller, which is mounted directly onto the motor shaft. The impeller creates centrifugal force.
  • The spinning impeller draws fluid into the pump through the suction inlet.
  • The centrifugal force generated by the rotating impeller causes the fluid to move outward and upward towards the outer edge of the impeller.
  • As the fluid moves outward, it gains velocity and kinetic energy due to the high-speed rotation of the impeller.
  • The fluid exits the impeller through the discharge outlet located at the periphery of the impeller.

Features

  • It has a cast iron body for structural rigidity and longevity.
  • This pump offers overload protection and also protects against overheating and electrical faults.
  • It features a carbon / ceramic mechanical seal to prevent leaks and ensure efficient operation.
  • The pump's semi-open impeller design efficiently handles solids and debris, reducing clogging and improving pump efficiency.

Compatible Accessories

  • Dayton 3ACE6 Shaft Seal: It is used in machinery and equipment with rotating shafts requiring sealing to prevent leakage.

Certifications

certificate

Frequently Asked Questions

What is the operating temperature of this Dayton 2ZWN9 centrifugal pump?

It has an operating temperature ranging from 40 to 200 degrees F.

Is this centrifugal pump corrosion resistance?

Yes, it has an air-dry enamel paint coating that protects against corrosion.

What factors should I consider to select the right centrifugal pump for my application?

  • Type of fluid
  • Required flow rate
  • Pressure Specifications
  • Operating temperature
  • Pressure
  • Fluid viscosity

What safety precautions should I follow when working with centrifugal pumps?

  • Before performing maintenance or repair work, ensure that the pump is properly shut down and locked out to prevent accidental startup.
  • Use PPE kits, safety glasses, gloves, hearing protection, and protective clothing to guard against potential hazards.
  • Stay clear of moving or rotating components of the pump to prevent injury.
  • When working in confined spaces where pumps are installed, ensure adequate ventilation to prevent the buildup of hazardous fumes or gases.
  • Adhere to established safety guidelines and protocols for working with centrifugal pumps.
  • Ensure that personnel involved in operating or maintaining centrifugal pumps receive adequate training on safe practices and procedures.