Select Country
- Source Now
Ships within 2 days via
We deliver to your doorstep under DAP terms. Customs clearance is for your account
Business customers can apply for Net 30
No fees, No interest, Fast approval.
Payment
| Item | Line Volt Mechanical Tstat |
|---|---|
| Application | Heat And Cool |
| Bulb Dia. | 1/4" |
| Bulb Length | 2 1/4" |
| Capillary Length | 120" |
| Changeover Type | Manual |
| Color | Gray |
| Compatible System Type | Cooling Tower Sump Heaters |
| Contact Rating | 120/208/240/277V AC |
| Contact Rating Resistive @ 120v | 16A |
| Contact Rating Resistive @ 240v | 8A |
| Contact Rating Resistive @ 277v | 6.9A |
| Contact Type | Snap Action |
| Control Type | Screwdriver |
| Cooling Full Load @ 120v | 16A |
| Cooling Full Load @ 240v | 8A |
| Cooling Locked Rotor @ 120v | 96A |
| Cooling Locked Rotor @ 240v | 48A |
| Depth | 3 3/8" |
| Differential | 5°F |
| Differential Type | Fixed |
| Electrical Connection Type | Screw Terminal |
| Enclosure Color | Gray |
| Enclosure Material | Steel |
| Enclosure Nema Rating | 3R |
| Full Load Amps | 16A |
| Full Load Amps @ 120v | 16A |
| Full Load Amps @ 240v Ac | 8A |
| Height | 4 1/16" |
| Includes | Wrench |
| Inductive Amps @ 120v | 16A |
| Inductive Amps @ 208v | 9.2A |
| Inductive Amps @ 240v | 8A |
| Input Voltage | 120-277V AC |
| Locked Rotor Amps @ 120v | 96A |
| Locked Rotor Amps @ 240v | 48A |
| Maximum Control Temperature | 150°F |
| Maximum Operating Temperature | 190°F |
| Minimum Control Temperature | 0°F |
| Minimum Operating Temperature | -35°F |
|---|---|
| Mounting Direction | Horizontal, Vertical |
| Mounting Hole Di. | 1/4" |
| Mounting Hole Diameter | 1/4" |
| Mounting Type | Surface Mount |
| Number Of Cooling Stages | 1 |
| Number Of Heating Stages | 1 |
| Number Of Poles | 1 |
| Number Of Relay Control Output | 1 |
| Number Of Relay Inputs | 1 |
| Number Of Relay Outputs | 1 |
| Number Of Stages | 1 |
| Number Of Switches | 1 |
| Overall Depth | 3 3/8" |
| Overall Height | 4 1/8" |
| Overall Length | 4.062" |
| Overall Width | 4 1/8" |
| Pilot Duty Contacts | 125 VA |
| Pilot Duty Rating | 125 VA @ 24 to 600V AC |
| Remote Sensing Bulb Included | Yes |
| Remote Sensing Capability | Yes |
| Resistive Amps @ 208v Ac | 9.2A |
| Sensing Bulb Dia. | 9/32" |
| Sensing Bulb Length | 2 1/4" |
| Sensor Location | Remote |
| Sensor Type | Hydraulic Capillary Bulb Copper |
| Switch Action | Open/Close On Rise |
| Switch Ratings @ 120v Dc | 16A |
| Switch Type | SPDT |
| Temp. Sensitivity | -2°F to +2°F |
| Temperature Differential | 5°F |
| Temperature Scale | Fahrenheit, Celsius |
| Temperature Sensitivity | -2°F to +2°F |
| Thermostat Programmable | No |
| Thermostat Type | Rainproof Single Stage Controls |
| Voltage | 120-277V AC |
| Voltage Range | 120-277V AC |
| Width | 4 1/16" |
| Standards | CSA LR948/4813 02, UL E6688 |
| Height (cm) | 10.48 |
|---|---|
| Length (cm) | 8.57 |
| Width (cm) | 10.48 |
| HS Code | 9032100060 |
|---|---|
| Country Of Origin | MX |
| Weight (kg) | 1.215 |